OELMAIER Industrieelektronik offers different control units for MIG/MAG welding. Optional available is the range from simple control unit MS20-6 for control of wire feed with 2 steps up to the more comfortable control unit MSE2. This control unit has 2 step and 4 step-operation and program memory for synergy operation. Please see the full functional range on the back side.

|
|
|
Logic Controller
|
Thyristor Controller
|
 |
|
|
|
MS 20-2
|
MS 20-6
|
MSE 6
42V
MSE_SW1 inklusiv
|
MSE6
24V
MSE_SW1 inklusiv
|
MSE 1
|
MSE 2
|
MG4
|
MCB
|
 |
|
System / parts no.:
|
|
71302
|
71301
|
70594
|
70595
|
70414
|
70419
|
70480
|
70230
|
 |
|
|
|

|

|

|

|

|

|
|
|
|
|
Technical Data
|
|
|
|
|
|
|
|
|
|
|
Voltage supply
|
[V]
|
24/42
|
24/42
|
42
|
24
|
42
|
42
|
2x18AC
|
2x18AC
|
 |
|
Motor voltage
|
[V]
|
24/42
|
24/42
|
42
|
24
|
24-42
|
24-42
|
-
|
-
|
 |
|
Dimensions ( L x W )
|
[mm]
|
120x130
|
120x130
|
150x120
|
150x120
|
170x135
|
170x135
|
|
|
 |
|
Max. Motor power
|
[W]
|
120
|
120
|
150
|
100
|
200
|
200
|
|
|
 |
|
Output for magnetic valve and mains contactor
|
[V]
|
42
|
42
|
-
|
-
|
-
|
-
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Funktions
|
|
|
|
|
|
|
|
|
|
|
2 step
|
|

|

|

|

|

|

|
|
|
 |
|
4 step
|
|
-
|

|

|

|

|

|
|
|
 |
|
Spot time
|
|

|

|

|

|

|

|
|
|
 |
|
IWir bumback time
|
|

|

|

|

|
-
|
-
|
|
|
 |
|
Inching
|
|
-
|
-
|

|

|

|

|
|
|
 |
|
Creep in
|
|
-
|
-
|

|

|

|

|
|
|
 |
|
controlled wire feed
|
|

|

|

|

|

|

|
|
|
 |
|
Digitale RPM control
|
|
-
|
-
|

|

|

|

|
|
|
 |
|
Current limited motor power step
|
|

|

|
-
|
-
|
-
|
-
|
|
|
 |
|
Short circuit free motor end step
|
|
-
|
-
|

|

|

|

|
|
|
 |
|
Braking current control
|
|
-
|
-
|
-
|
-
|

|

|
|
|
 |
|
Synergy mode
|
|
-
|
-
|

|

|

|

|
|
|
 |
|
Gas pre-flow
|
|
-
|
-
|
-
|
-
|

|

|
|
|
 |
|
Gas past-flow
|
|
-
|
-
|
-
|
-
|

|

|
|
|
 |
|
Output for I > 0
|
|
- |
-
|
optional
|
optional
|

|

|
|
|
 |
|
Display for welding voltage
|
|
-
|
-
|
-
|
-
|
-
|

|
|
|
 |
|
Display for welding current or wire speed
|
|
-
|
-
|
-
|
-
|
-
|

|
|
|
 |
|
Display füor welding voltage or wire speed
|
|
-
|
-
|
-
|
-
|

|
-
|
|
|
 |
|
Display of synergy mode on LED line (gas, wire, etx.)
|
|
-
|
-
|
-
|
-
|

|

|
|
|
 |
|
No of program sets
|
|
|
|
11
|
11
|
30
|
30
|
|
|
|
|
Special Features
|
|
|
|
|
|
|
|
|
|
|
Hotstart
|
|
|
|
|
|
|
|
-
|

|
 |
|
Mains voltage compensation
|
|
|
|
|
|
|
|

|

|
 |
|
Intigrated thyristor control
|
|
|
|
|
|
|
|

|

|
 |
|
Control voltage
|
|
|
|
|
|
|
|

|

|
 |
|
|
|
|
Subject to technical and / or optical changes
Text and graphics according to the technical status of printing. Right of technical modification reserved. Misprints and errors excepted.
|
|