AWS Welding Systems with AC, DC and for plasma welding
By these welding systems for the field of automatization it is possible to combine best welding current supply sources with a host processor and develop a welding system which can be configurated by the customer and meet the highest demands for precision and reproducibility.
The customer can diagnose and correct possible errors local by the integrated diagnostic system. These welding systems are available for welding with AC, with DC and for plasma welding.
|
|

|
|
 |
PDF-Download Datasheet E
|
|
|
AWS 210 DC
|
AWS 210 ACDC
|
AWS 250 DC
|
AWS 250 ACDC
|
AWS 300 DC
|
AWS 300 ACDC
|
AWS 100 PLASMA
|
AWS 210 PLASMA
|
AWS 300 PLASMA
|
 |
|
System / part no.:
|
|
70865
|
70866
|
70897
|
70898
|
70868
|
70869
|
70899
|
70827
|
70828
|
 |
|
Inverter
|
|

|
 |

|

|

|

|

|

|

|
|
|
Technical Data
|
|
|
|
|
|
|
|
|
|
|
|
1/N/PE AC 230 V
|
|

|
 |
-
|
-
|
-
|
-
|

|

|
-
|
 |
|
3/PE AC 400 V
|
|
-
|
- |

|

|

|

|
-
|
-
|

|
 |
|
I 1
|
[A]
|
21
|
21
|
11
|
11
|
20
|
20
|
9
|
23
|
21
|
 |
|
S1
|
[kVA]
|
4,9
|
4,9
|
7,8
|
7,8
|
13,5
|
13,5
|
2,1
|
5,3
|
14,5
|
 |
|
Pilot current
|
[A]
|
-
|
-
|
-
|
-
|
-
|
5-10
|
5-10
|
5-10
|
-
|
 |
|
fuse, slow
|
[A]
|
16
|
16
|
16
|
16
|
20
|
20
|
16
|
16
|
20
|
 |
|
U 0
|
[V]
|
85
|
85
|
86
|
86
|
86
|
86
|
106
|
106
|
106
|
 |
|
Setting range I2
|
[A]
|
3-200
|
3-200
|
3-250
|
3-250
|
3-300
|
3-300
|
3-100
|
3-200
|
3-300
|
 |
|
Max ED*
|
[%]
|
50
|
50
|
65
|
65
|
50
|
50
|
100
|
50
|
50
|
 |
|
Setting range balance
|
[%]
|
-
|
25-75
|
-
|
25-75
|
-
|
25-75
|
-
|
-
|
-
|
 |
|
Setting range frequenz
|
[Hz]
|
-
|
30-200
|
-
|
30-200
|
-
|
30-200
|
-
|
-
|
-
|
 |
|
Dimensions legth
|
[mm]
|
660
|
660
|
660
|
660
|
660
|
660
|
660
|
660
|
660
|
 |
|
Dimensions width
|
[mm]
|
360
|
360
|
360
|
360
|
360
|
360
|
360
|
360
|
360
|
 |
|
Dimensions height
|
[mm]
|
380
|
380
|
380
|
380
|
380
|
380
|
380
|
380
|
380
|
 |
|
Weight
|
[kg]
|
28,5
|
30
|
30
|
34
|
30,5
|
34,5
|
31
|
31
|
33
|
 |
|
Made per EN 60974-1
|
|

|

|

|

|

|

|

|

|

|
 |
|
S
|
|

|

|

|

|

|

|

|

|

|
|
|
Application
|
|
|
|
|
|
|
|
|
|
|
|
TIG DC
|
|

|

|

|

|

|

|
-
|
-
|
- |
 |
|
TIG AC
|
|
-
|

|
-
|

|
-
|

|
- |
-
|
-
|
 |
|
Plasma welding
|
|
-
|
-
|
-
|
-
|
-
|
-
|

|

|

|
 |
|
| |
Special features
|
|
|
|
|
|
|
|
|
|
|
 |
|
PFC
|
|

|

|
-
|
-
|
-
|
-
|

|

|
-
|
 |
|
Mains current limitation
|
|

|

|

|

|

|

|

|

|

|
|
|
Functions
|
|
|
|
|
|
|
|
|
|
|
|
Error diagnostic system
|
|

|

|

|

|

|

|

|

|

|
 |
|
Operation via PC
|
|

|

|

|

|

|

|

|

|

|
 |
|
"manual mode" possible
|
|

|

|

|

|

|

|

|

|

|
 |
|
free configurable via interface
|
|

|

|

|

|

|

|

|

|

|
 |
|
|
|
* dependent on installation space
Subject to technical and / or optical changes
Text and graphics according to the technical status of printing. Right of technical modification reserved. Misprints and errors excepted.
|
|